Home Upcoming
NEW
Home Upcoming
141 views
HSPA: 2.0 CE Points
(certified until 29 Oct 2025)
7 Nov 2023
Event Details

RUMED Online Training Program:
The complexity of instrument reprocessing and related processes is increasing, requiring a deep understanding of correlations within various workflows. This expertise is crucial for making informed decisions and upholding the high quality standards in our daily work at RUMED. Achieving this requires a strong foundation of technical and procedural knowledge. To meet these demands, the RUMED Academy offers a comprehensive online training program consisting of two levels: 'Reprocessing Technician RUMED (Level 1)' and 'Senior Processing Technician RUMED (Level 2)'.

The modules are conducted in English, available also in Spanish in Latin America, and delivered by experienced international experts with extensive knowledge and practical experience in the field of application in the operating room (OR) and instrument reprocessing. The content of the modules is based on the comprehensive DGSV and HSPA courses, ensuring a well-rounded and relevant training experience.

Reprocessing Technician RUMED (Level I):
The Level I program consists of 14 individual modules (see below “Module Overview”). The target group is RUMED managers, RUMED technicians and other employees in RUMED with proficient English/Spanish language skills and practical experience in a reprocessing structure for medical devices.

Module 4.0: Sterilization:
Sterilization is a critical process in hospitals to ensure the safety of patients and healthcare workers. It involves the elimination or removal of all microorganisms, such as bacteria, viruses, and fungi, from medical devices, instruments, and surfaces. Sterilization methods vary depending on the type of equipment or Instruments and the intended use. The most common methods used in hospitals are steam sterilization and chemical sterilization. The effectiveness of the sterilization process is dependent on several factors, such as the type and level of contamination, the exposure time and temperature, and the quality of the sterilization equipment. Routine checks and batch monitoring are important to ensure the functionality of the sterilizer. If medical devices and instruments are not properly sterilized, healthcare-associated (nosocomial) infections can occur, which can have serious consequences for patients.

Certification: 
Upon successful completion of this module, a certificate with 2.0 CE points by the HSPA is issued as proof of achievement. Each module concludes with a knowledge quiz. Once you have completed all modules and provided the corresponding certificates to the RUMED Academy, you will be awarded the Reprocessing Technician RUMED (Level 1) certificate.  

Participation Cost: 
€ 80.00 per Module

Module Overview (Level I):
1.0 Standards, Laws and Regulation
2.0 Hygiene and Microbiology
3.0 Cleaning and Disinfection I
3.1 Cleaning and Disinfection II
4.0 Sterilization
5.0 Proper Machinery Working
6.0 Structure and Design of RUMED and its Processes
7.0 Quality Management and Validation I
8.0 RUMED Management I
8.1 RUMED Management II
9.0 Material and Instrument Sciences I
10.0 Packaging and Sterile Barrier Systems I
10.1 Packaging and Sterile Barrier Systems II
11.0 Processing of Medical Devices in the Supply Chain I

see more see less
Experts
Christina Lehmann
RecoTec-Software GmbH - Weilheim i. Obb., Germany​
Philip Lips
​KLS Martin Group - Tuttlingen, Germany​
More details
see more see less
Partners Event Agenda
09.30 CET | PART 1
Welcome & Introduction
2 min
Definition of Sterilization and Sterile
5 min
D-Value and Log
5 min
Conclusion of Kill-Kinetics
5 min
History of Sterilization
5 min
Methods of Sterilization - Radiation
3 min
Methods of Sterilization - Filtration
3 min
Methods of Sterilization - Formaldehyde Sterilization
3 min
Methods of Sterilization - Ethylene Oxide Sterilization
3 min
Methods of Sterilization - Hot Air Sterilization
3 min
Methods of Sterilization - Plasma Sterilization
3 min
Review
5 min
Steam Sterilization
5 min
Steam Sterilization - Video
5 min
Live Discussion - Voting, Q&A
5 min
10.30 CET | BREAK
10 min
10.40 CET | PART 2
Sterilization Process
3 min
Sterilization Programs
3 min
How to Assemble a Batch
3 min
Requirements for a Batch Release
3 min
Review
4 min
Routine Check
3 min
Vacuum Test
3 min
Bowie Dick Test
3 min
Batch Monitoring
3 min
Other Tasks of the Employees
3 min
Validation
4 min
Review
4 min
Summary and Conclusion
3 min
Live Discussion - Voting, Q&A
5 min
Key Takeaways
3 min
GET CERTIFIED (INDIVIDUAL)
30 min
I Will Learn To
Exercise the methods of sterilization
Understand the steam differences
Identify the stages of a steam sterilization process
Perform routine checks of a sterilizer
Recognise requirements for a batch release
more like this
09:52
Winglet Journal Club – #017: Osteoporotic Thoraco-Lumbar Fractures of the Spine - The OF Classification
Clinical Evaluation of the Osteoporotic Fracture Treatment Score (OF-Score): Results of the Evaluation of the Osteoporotic Fracture Classification, Treatment Score and Therapy Recommendations (EOFTT) Study (Ullrich et al., 2023)
  • Provided by
  • Date
    Apr 2024
  • Format
    ScienceCast
  • Price
    0.99 €
Winglet Journal Club – #012: Anterior Shoulder Instability in Patients over 50
Natural History of First-Time Anterior Shoulder Dislocation in Patients Older Than 50 Years: A Study of 179 Patients With a Mean Follow-up of 11 Years (Smartt et al., 2022)
  • Provided by
  • Date
    Jul 2023
  • Format
    ScienceCast
  • Price
    0.99 €
  • Provided by
  • Date
    Jan 2024
  • Format
    ScienceCast
  • Price
    0.99 €
08:55
Winglet Journal Club – #013: Influence of Rotational Deformities of the Lower Extremity on Patellofemoral Instability
Effect of Lower Extremity Torsion on Clinical Outcomes After Medial Patellofemoral Ligament Reconstruction and Tibial Tubercle Transfer for Recurrent Patellofemoral Instability (Yi Qiao et al., 2023)
  • Provided by
  • Date
    Sep 2023
  • Format
    ScienceCast
  • Price
    0.99 €
Winglet Journal Club – #010: Lateral Extra-Articular Tenodesis in Addition to ACL Reconstruction
Anterior Cruciate Ligament Reconstruction Alone Versus With Lateral Extra-Articular Tenodesis with Minimum 2-Year Follow-Up (Onggo et al., 2021)
  • Provided by
  • Date
    Sep 2022
  • Format
    ScienceCast
  • Price
    0.99 €
Login
Good to see you
Don't have an account?
forgot password?
Don't have an account
Signup
The Netflix for Doctors
Internet Explorer is no longer supported
To get the best possible experience using our website, use one of these popular browsers.
Just click on the icons to get to the download page